MZX-LED series LED fluorescent attachment is self-researched by Micro-shot company. It is designed to upgrade stereo microscope to fluorescence functional.The LED attachment integrates fluorescence filters and light source in one unit, switch fluorescence observation and bright field observation by wheel. Digital screen shows and remember each channel light intensity. What is more, it keeps original stereo microscope optical performance no matter depth of field or field of view.
Spesifikasi: Types:Single channel Item No: MZX-G-LED LED lamps: Green Filter Groups: Green Compatible microscopes: Olympus CX/BX Nikon Eclips/E100/E200/Ci-L Leica DM500/DM750/DM1000 Zeiss PrimoStar /A1 Sunny EX30 Motic BA310/Panthera C Model:G LED lamp:Green Filter wavelength: Excitation:530/40nm Dichroic mirror:570nmLP Emission: 590nmLP Recommend Application: PI / EB / EH /TRITC Light source: Blue / UV: 3W LED cold lamp for each filter group Green / Yellow : 5W LED cold lamp for each filter group Observation: Fluorescence Bright field & phase contrast by microscope original lighting Operation: Lever control B/G(Y)/U(O) Power control: Rota-table knob, continuously adjustable brightness Input power: 12V 2A Light baffle: Orange color plastic light baffle Remark*: Single excitation mode are long pass filter LED: Green Filter type: Band-pass Excitation filter: 475/40nm Dichroic mirror: >500nm Emission filter: 535/45nm
ZEISS Xradia CrystalCT® computed tomography platform uniquely augments this powerful imaging technique with the ability to reveal crystallographic grain microstructures, transforming the way polycrystalline materials (such as metals, additive manufacturing, ceramics, pharmaceuticals and others) can be studied, leading to newer and deeper insights for your materials research.
ZEISS Xradia Context® micro-computed tomography (microCT) is an easy-to-use system for analysis of all types of samples. A high-array detector enables high resolution of fine details even with relatively large imaging volumes. The system features a large field of view, rapid sample mounting and alignment, streamlined acquisition workflow and fast exposure and data reconstruction times.
In XRM, contrast depends on the material being imaged and the X-ray energy used. The Xradia Ultra family comprises of Xradia 800 Ultra, operating at 8 keV photon energy, and Xradia 810 Ultra, operating at 5.4 keV. In general, lower energy X-rays are absorbed more strongly and therefore will provide you with higher contrast for most materials. Thus, as long as transmission remains sufficient, you will experience resulting image quality and/or throughput that are greatly improved with Xradia 810 Ultra.