The Hi2300 is an auto ranging EC/TDS/Salinity and temperature benchtop meter. The meter utilizes a four-ring potentiometric conductivity probe with platinum sensors to offer versatility over typical amperometric designs. By utilizing the four-ring probe, it is possible to measure very low or very high conductivity levels without having to change probes. The Hi2300 also offers three options for temperature compensation, as well as an adjustable temperature coefficient (β) and TDS factor. GLP capabilities and PC connectivity via USB provide users with a simple way to organize and manage their data
EC Range : 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)** EC Resolution : 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm EC Accuracy : ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater) EC Calibration : automatic, one point with six memorized values (84, 1413, 5000, 12880, 80000, 111800 μS/cm) TDS Range : 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor TDS Resolution : 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L TDS Accuracy : ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) Temperature Correction Coefficient : selectable from 0.00 to 6.00%/°C (EC and TDS only) EC to TDS Conversion Factor : 0.40 to 0.80 (default value is 0.50) Salinity (% NaCl) Range : 0.0 to 400.0% NaCl Salinity (% NaCl) Resolution : 0.1% NaCl Salinity (% NaCl) Accuracy : ±1% of reading Salinity (% NaCl) Calibration : one point, with HI7037 calibration solution (optional) Temperature Range : -20.0 to 120.0 ºC Temperature Resolution : 0.1 °C Temperature Accuracy : ±0.4°C (±0.8°F) (excluding probe error) EC/TDS Probe : HI76310 platinum, four-ring conductivity/TDS probe with internal temperature sensor and 1 m (3.3’) cable (included) Logging Type : log-on-demand Logging Memory : 500 sample Connectivity : opto-isolated USB GLP : yes Power Supply : 12 VDC adapter (included) Environment : 0 to 50°C (32 to 122°F), RH max 95% non-condensing Notes:*Uncompensated conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation. Dimensions : 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”) Weight : 1.3 kg (2.9 lbs)
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.