The Hi5521 is an advanced research grade benchtop pH/mV/EC/TDS/Salinity/Resistivity meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The Hi5521 is rich in features including data logging, alarm limits, comprehensive GLP, and many more while retaining simplicity in use with both dedicated key for routine operation and virtual keys that guide the user through setup options. The Hi5521 ensures confidence in pH measurements with the exclusive Hanna Instruments CAL Check™ feature that alerts the user to potential problems during calibration including if the buffer is contaminated or the probe needs to be cleaned
pH Range : -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH pH Resolution : 0.1 pH / 0.01 pH / 0.001 pH pH Accuracy : ±0.1 pH / ±0.01 pH / ±0.002 pH ± 1LSD pH Calibration : Up to five-point calibration, eight standard buffers available (pH 1.68, 3.00, 4.01, 6.86, 7.01,9.18, 10.01, 12.45), and five custom buffers pH Temperature Compensation : automatic or manual from -20.0 to 120.0 °C mV Range : ±2000.0 mV mV Resolution : 0.1 mV mV Accuracy : ±0.2 mV ± 1LSD mV Relative Offset : ±2000.0 mV EC Range : 0.000 to 9.999 μS/cm, 10.00 to 99.99 μS/cm, 100.0 to 999.9 μS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm actual EC* EC Resolution : 0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm EC Accuracy : ±1% of reading (±0.01 μS/cm) EC Calibration : automatic standard recognition (0.000 μS/cm, 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm) or user standard; single point or multi-point calibration TDS Range : 0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS* (with 1.00 factor) TDS Resolution : 0.001 ppm, 0.01 ppm, 0.1 ppm, 1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt TDS Accuracy : ±1% of reading (±0.01 ppm) EC/TDS Temperature Compensation : disabled, linear and non-linear (natural water) Temperature Correction Coefficient : 0.00 to 10.00 %/°C Reference Temperature : 5.0 to 30.0 °C Cell Constant : 0.0500 to 200.00 Cell Type : 4 cells Salinity (% NaCl) Range : 0.0 to 400.0 % Salinity (% NaCl) Resolution : 0.1 % Salinity (% NaCl) Accuracy : ±1% of reading Salinity (PSU) Range : 0.00 to 42.00 psu Salinity (PSU) Resolution : 0.01 Salinity (PSU) Accuracy : ±1% of reading Salinity (PSU) Calibration : 1 point (with HI7037 standard) Salinity Range : 0.00 to 80.00 ppt Salinity Resolution (ppt) : 0.01 Salinity Accuracy (ppt) : ±1% of reading Resistivity Range : 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cmResistivity Resolution : 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm* Resistivity Accuracy : ±2% of reading (±1 Ω•cm) Temperature Range : -20.0 to 120.0 ºC**; -4.0 to 248.0 ºF**; 253.15 to 393.15 K** Temperature Resolution : 0.1 °C, 0.1 °F, 0.1 K Temperature Accuracy : ±0.2 °C; ±0.4 °F; ±0.2 K (without probe) Input Channels : 2 (pH/mV; onductivity/Resistivity/ TDS/Salinity) pH Electrode : HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included) EC/TDS Probe : HI76312 platinum, four-ring EC/TDS probe with and 1 m (3.3’) cable (included) Temperature Probe : HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included) Logging Type : Automatic, Manual, AutoHold Logging Memory : Up to 100 lots, 50,000 records max/lot; maximum 100,000 data points / channel Logging Interval : 14 selectable between 1 second and 180 minutes Connectivity : Opto-isolated USB GLP : yes (GLP Channel 1:Electrode offset / slope, calibration points, calibration time stamp, GLP Channel 2 : Probe cell constant / offset, reference temperature, compensation coefficient, calibration points, calibration time stamp) Calibration Timeout Reminder : yes USP Compliant : USP <645> Application Profiles : up to 10, 5 each channel Display : Color Graphic LCD 240 x 320 pixels, 8 keys capacitive touch keyboard Power Supply : 12 VDC adapter (included) Environment : 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing) Notes : *Uncompensated conductivity (or TDS) is the conductivity (or TDS) value without temperature compensation. **Reduced to actual probe limits Dimensions : 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) Weight : 1.2 Kg (2.6 lbs)
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.