The Hi98195 is a waterproof portable logging multiparameter meter that monitors up to 10 different water quality parameters including 5 measured and 5 calculated. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged. The complete system is simple to setup and easy to use. The HI98195 is supplied with all necessary accessories and packaged in a durable carrying case
pH Range : 0.00 to 14.00 pH pH Resolution : 0.01 pH pH Accuracy (@25°C/77°F) : ± 0.02 pH pH Calibration : automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer mV Range : ± 600.0 mV mV Resolution : 0.1 mV mV Accuracy : ± 0.5 mV ORP Range : ± 2000.0 mV ORP Resolution : 0.1 mV ORP Accuracy (@25°C/77°F) : ± 1.0 mV ORP Calibration : automatic at one custom point (relative mV) Temperature Range : -5.00 to 55.00 °C; 23.00 to 131.00 °F; 268.15 to 328.15 K Temperature Resolution : 0.01 °C; 0.01 °F; 0.01 K Temperature Accuracy (@25°C/77°F) : ± 0.15 °C; ± 0.27 °F; ±0.15 K Temperature Calibration : automatic at one custom point EC Range : 0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm) EC Resolution : auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01 EC Accuracy (@25°C/77°F) : ±1% of reading or ±1 µS/cm whichever is greater EC Calibration : automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point TDS Range : 0 to 9999 ppm (mg/L); 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor) TDS Resolution : manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt) TDS Accuracy (@25°C/77°F) : ±1% of reading or ±1 ppm (mg/L), whichever is greater TDS Calibration : based on conductivity calibration Resistivity Range : 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm Resistivity Accuracy (@25°C/77°F) : dependent on resistivity reading Resistivity Calibration : based on conductivity calibration Salinity Range : 0.00 to 70.00 PSU Salinity Resolution : 0.01 PSU Salinity Accuracy (@25°C/77°F) : ±2% of reading or ±0.01 PSU whichever is greater Salinity Calibration : based on conductivity calibration Temperature Compensation : automatic from -5 to 55 °C (23 to 131 °F) Log Feature : 45,000 records (continuous logging or log-on-demand of all parameters) Connectivity : USB to PC with HI9298194 Hanna software installed GLP : Yes Power Supply : 1.5V AA batteries (4) Power Consumption : approximately 360 hours of continuous use without backlight (50 hours with backlight) Environment : 1 to 50°C (32 to 122°F); RH 100% (IP67) Dimensions : 186 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) Weight : 401 g (14.2 oz.)
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our compact and powerful benchtop model was developed to provide simplicity with excellent on-site usability.